Mon-Fri, 8am-6pm

Endotracheal Tubes

VentiSeal™

A high volume low pressure cuff, with a thin ultra-smooth cuff wall that conforms to the tracheal contours for an effective seal.

  • Sterile
  • Single Use
  • Latex Free
  • DEHP Free

Soft Rounded Distal Tip
Gentle, bevelled tip reduces potential for soft tissue trauma during insertion, with minimal increase in flow resistance.

Large Murphy’s Eye
Keeps airway patent should tip become occluded and large size of hole softens tip, reducing risk of soft tissue trauma.

Circumferential Vocal Cord Markers
Double guide lines are clearly seen from all angles, facilitating safe and accurate cuff placement below the vocal cords.

Distance Markings
Earlier indication of depth during insertion with clear, bold print and check for any possible movement or dislocation of the ET tube during the procedure.

Kink Resistant
Retains tube patency for patient safety, whilst softening at body temperature to conform to patient’s respiratory tract.

Coloured Inflation Line
For quick identification to differentiate from other tubing.

Rapid Inflation Pilot Balloon
Small balloon size, means less air is pushed into cuff, reducing potential tracheal wall necrosis when checking cuff inflation using the “squeeze” test.

Simple Verification
Small and rounded shape of the balloon gives a more responsive and tactile feel to the user for inflation check.

Reinforced Central Rib
Prevents complete collapse of the pilot balloon, during rapid deflation ensuring line to cuff is always open.

VentiSeal™ Images

Standard Cuffed ET Tubes

Cuff size and shape of the low pressure endotracheal tube, facilitates quick and easy intubation, ideal for short term intubation and emergency situations.

Kink Resistant
Retains tube patency for patient safety, whilst softening at body temperature to conform to patient’s respiratory tract.

Depth Guide
The double line guide facilitates safe and accurate cuff placement below the vocal cords.

Pilot Balloon
In addition to providing a tactile check on cuff inflation, the pilot balloon clearly identifies the tube size.

High Resolution Radiopaque Line
Guarantees easy and accurate identification of tube position and location during X-ray.

Standard Cuffed ET Tubes Images

Uncuffed

A comprehensive range of uncuffed endotracheal tubes provide safety and comfort for patients and intubation with total confidence.

Clear Positioning Guides
2.0mm to 5.0mm ID tubes feature a single Depth Guide to identify correct placement. The orientation guide indicates position of the Murphy’s Eye and tube tip.

Vocal Cord Placement Markers
Sizes 5.5mm and above feature the same double line as the VentiSeal tubes, making them clearly visible from all angles, facilitating safe and accurate tube placement.

Smooth Bevelled Tip
Rounded bevelled tip reduces risk of damage to vocal cords during intubation.

Distance Markers
Distance Markers start at 3cms for safe and accurate placement in the smallest patients.

High Resolution Radiopaque Line
For easy and accurate identification of tube position during x-ray.

Kink Resistant
Maintains tube patency whilst softening at body temperature to conform to the patient’s respiratory tract.

Uncuffed Images

ET Tube Holder

Securely retains the position of all sizes of ET Tubes.

ET Tube Holder Images

Jaw Opener

To be used with an ET Tube when the patient has ‘Teeth Clench’.

Jaw Opener Images

FLEXICARE ENDOTRACHEAL TUBES BROCHURES

This site is intended for healthcare professionals, and those working in the healthcare industry. By visiting this site, you agree to our terms of use. Terms of Use