Rhino 4000 series: German-Engineered Diagnostics

RHINOMANOMETRY Rhino 4000-M (PC-based module)

With the Rhino 4000-M PC-module a measuring-method was evolved, allowing the adaptation via nose plugs and alternatively via a face mask. The method is used in the doctors practice as well as in clinics. All functions, data and diagrams are shown on the PC monitor. Herewith the results can be verified before documentation to avoid misprintings.

The time-saving adaptation via nose-plugs allows a direct use at the doctors working-place, so the measurement fits into the normal examination. All calculation of flow, pressure, percentage and resistance-coefficient are done in realtime, so by the end of the measurement the complete results are present. Persons with bearts, long hair and children with fear of masks, can be measured without any problems. For clinical use a face-half-mask is available. During the measurement the intensity of breathing can be controlled via two measuring bars. The measurement is carried out anterior under the
physiological conditions of self-breathing and allows a quantitatively objective statement about the resistance-status of the nose.

Because of microprocessor controlling the use is very easy, so the measurement can be carried out by the medical personnel. The mean of max. five flow curves is calculated and shown in the diagram as flow-pressure curves. Also the flow-values for a difference-pressure of 75 Pa, 150 Pa and 300 Pa are calculated and shown in the screen, together with the percentage of right- and left-side flow. For clinical use the coefficient of the resistance is calculated.

All data and measured curves can be stored on hard disc, if the device is connectet to a PC. For printouts is used an extremely fast digital-printer, working very noiseless and economical.

RHINOMANOMETRY Rhino 4000 (stand-alone device)

With the Rhino 4000 a measuring method was evolved, which allows the adaptation via noseplugs and alternatively via face-mask. The method is used in the doctors practice as well as in clinics. All functions, data and diagrams are shown at a LCD display. Herewith the results can be verified before documentation to avoid miss-printings.

The time-saving adaptation via nose-plugs allows a direct use at the doctors working-place, so the measurement fits into the normal examination. All calculation of flow, pressure, percentage and resistance-coefficient are done in realtime, so by the end of the measurement the complete results are present. Persons with bearts, long hair and child-ren with fear of masks, can be measured without any problems. For clinical use a face-half-mask is available. During the measurement the intensity of breathing can be controlled via two measuring bars. The measurement is carried out anterior under the physiological conditions of self-breathing and allows a quantitatively objective statement about the
resistance-status of the nose.

Because of microprocessor controlling the use is very easy, so the measurement can be carried out by the medical personnel. The mean of max. five flow curves is calculated and shown in the diagram as flow-pressure curves. Also the flow-values for a difference-pressure of 75 Pa, 150 Pa and 300 Pa are calculated and shown in the screen, together with the percentage of right- and left-side flow.

For clinical use the coefficient of the resistance is calculated. For printouts, an extreme fast digital printer, woking very noiseless and economical is used. All data and diagrams can be stored on a hard disk if the device is connected to a PC-system (optional).

Additional Rhinomanometry Information

Rhinomanometry

System: PC module with USB 2.0 interface:
System requirements: Pentium PC min. 500 MHz, USB 2.0 Port, Windows XP, 7, 8, 10 (32/64 Bit)
Method: anterior self-breathing
Airflow: 0 - 900 ml /s in- and exspiration
Pressure difference: 0-50 daPa
Function control: two measuring-bars in the display
Averaging: max. 5 flow-curves
Pressure calibration: automatic before start, manual
Visualization: diagram and numeric values
Automatic calculation of: • pressure in daPa
• flow in ml /sec incl. total-flow
• percentage
• resistance-coefficients
• Point 2-5 at 75, 150 and 300 daPa
Dimensions: 330 x 80 x 265 mm (WxHxD)
Power supply: 13,2 V, external power supply 100-240 V, 50/60 Hz, 30 W
Accessories: 12 nose-plugs (olives), 2 flow-probes, 2 sets of hoses, foot pedal, probe holder, USB cable, power supply, nstallations-CD, manual